Best-Practices to Prevent a RoundTrip

Follow

Scope

This article describes best-practices you can take to prevent having to order a RoundTrip for a Datto appliance.

Large Recovery Points

A common reason that partners order RoundTrips is when one or more large or full backups happen on their Datto device, instead of a normal incremental backup. When this happens, the backup needs to be replicated to the cloud by the appliance, but bandwidth limitations often prevent replication within a reasonable timeframe. See Explaining The Inverse Chain And Investigating Large Recovery Points for more information about diagnosing and preventing large recovery points.

Check the Default Transmit Limit

Through the Datto appliance GUI, navigate to the Off-Site Synchronization tab, and make sure that the Default Transmit Limit value is set to the correct amount. Run a speed test by clicking the Start Speed Test button. When it finishes, the speed will populate in the box next to the Default Transmit Limit box.

Datto recommends a default transmit speed of at least 100 Kilobytes (1 Megabit) per second per 1TB of protected storage. The higher the limit, the faster the device can be synced. The autoconfigure sets the bandwidth to 50% of the current available upstream bandwidth; this is done so the device does not interfere with other actions on the network.

offsitesync.png

Figure 1: Off-site sync bandwidth limit


Check the Off-Site Sync Schedule

On the Off-Site Synchronization tab, make sure that the off-site sync schedule is not throttling the Datto appliance's bandwidth more than necessary at any given time.

syncschedule.png
Figure 2: Off-site sync scheduling

If you need to make a change to the schedule, use the Backup at value in the Speed field, instead of the Pause Backup value unless absolutely necessary. The Pause function will stop an offsite sync in progress, and cause it to restart from the beginning when it resumes. This can cause a loop of continuous offsite syncs of the same point, which will then cause the appliance's overall offsite synchronization to fall behind.

Check the Cloud Backup and Retention Policy

In the Backup and Retention Settings section of the Datto appliance GUI, make sure that the number of points the device transmits offsite in a day is compatible with your available bandwidth.

cloudbackupandretention.png

Figure 3: Cloud backup and retention policy settings

If you send more than one point in a day, and offsite sync isn’t able to keep up because of bandwidth limitations, your cloud sync will start to fall behind, and the local backup points flagged for offsite replication will accrue.

If you have attempted all of the above recommendations and are still experiencing offsite synchronization issues, please contact Datto Technical Support.

 


Was this article helpful?

0 out of 0 found this helpful

You must sign in before voting on this article.

Want to talk about it? Head on over to our Community Forum!