MP60 Release Notes

Follow

Topic

This article contains all firmware release notes for the Datto MP60.

To ensure proper product operation, Datto recommends keeping your MP60's firmware updated to the latest release.

Environment

  • Datto Managed Power MP60

Releases

Release Notes

6.4.12 - August 15, 2018

Improvements:

  • The Ping Test now uses ICMP instead of HTTP + Curl to communicate to devices.

Bug Fixes:

  • Resolved an issue where scheduled events failed to occur.

6.4.9 - June 7, 2018

Improvements:

  • Improved mechanisms to more accurately report surge depletion.
  • Improved reliability of reading individual port state.

Known issues

  • If a port is disabled, and a schedule is configured to power cycle that port, the port will temporarily be enabled until the next check-in.  

6.4.8 - May 1, 2018

Improvements:

  • The default power cycle delay (the time from power off to power on when a user power cycles an individual port) is now 5 seconds.

Bug Fixes:

  • Resolved an issue where the LED on the MP60 blinked white indefinitely, despite checking in successfully.
  • Resolved an issue where multiple simultaneous scheduled actions fail to execute as expected.

Known Issues:

  • When switching between Ethernet/WiFi modes, the LED will not change color immediately.
  • If the MP60 is rebooted, all device ping tests will fail while the MP60 is booting up. All devices associated with a ping test will have its outlet power cycled.
  • If the maintenance window is set to 24 hours, the ping test will never fail, as it does not run by default during a maintenance window.

6.4.6 - April 26, 2018 (Initial Release)

  • Initial release